Experimental Study on Field Shrinkage of Deck Panel of Composite Girder Cable-stayed Bridge

Wenhao Yu 
Keywords: cable-stayed bridge; deck panel; shrinkage test.

Abstract

In order to study the shrinkage performance of the deck panel of the composite girder cable-stayed bridge, the shrinkage test of the deck panel members of the real bridge was carried out in the field with the background of the Malukou Great Bridge, comparing the difference between the shrinkage values measured in the test and the theoretically calculated values of shrinkage in the various specifications, and finally the shrinkage equations and curves of the deck panel in 180d were fitted based on the test data. The results show that: on 180d, the shrinkage strain calculated by JTG D62-2018, the current design specification used for highway bridges in China, is only 66.30% of the test shrinkage, and the small prediction of bridge deck shrinkage may cause problems in terms of structural cracking; based on the large differences between various specifications for the shrinkage strain of bridge decks, It is recommended to use the actual shrinkage strain measured by the bridge deck shrinkage test as the real shrinkage curve as the data source to accurately assess the deformation and stress state of the bridge deck.